Gas Generator CG132B-16

The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.<br>
<br>
Highly efficient with low operating and installation costs and lubricant consumption, the Cat CG132B gas generator set is available with outputs from 400kW to 800kW and comes with the Total Plant and Energy Management (TPEM) system.

Maximum Continuous Rating
800 kW @1.0pf
Fuel Type
Natural Gas, Biogas
Maximum Electrical Efficiency
43.5% / 42.6%
Maximum Standby Rating
800 kW

Specs

Generator Set Specification

Maximum Continuous Rating
800 kW @1.0pf

Generator Set Specifications

Fuel Type
Natural Gas, Biogas
Maximum Electrical Efficiency
43.5% / 42.6%
Maximum Standby Rating
800 kW
Frequency
50 / 60 Hz
RPM
1500 / 1800 rpm

Engine Specifications

Engine Model
CG132
Displacement
2135.8in³
Aspiration
TA
Bore
5.2in
Stroke
6.3in

Generator Set Dimensions

Length
165in
Width
70in
Height
85in
Dry Weight - Genset
NaNlb

Features

Lower Operating Costs

Smaller footprint

Cat Total Electronic Management System

Flexible Fuel Usage

Standard Equipment

  • Air Inlet
    • Turbocharger with a water-cooled bearing case for all cylinder
    • One-element single-stage air cleaner with enclosure and sevice indicator
  • Control Panels
    • TPEM (Total Plant & Energy Management System)
  • Cooling
    • ANSI/DN customer flange connections for JW inlet and outlet
    • Flange connections for JW inlet and outlet
    • Jacket water and SCAC thermostats
    • Electrical jacket water and aftercooler coolant pump
    • flange connections for JW inlet and outlet
    • ANSI/DN customer flange connections for JW inlet and outlet
    • Cat flanges on SCAC circuit
  • Exhaust
    • Exhaust waste gate for the CG132B-16
    • Closed crankcase ventilation system
    • PEARL/Low resistence exhaust system
  • Fuel System
    • Electronic fuel metering valve
    • Pre-chamber spark plugs
    • Electronic fuel metering valve
    • Independently controlled cylinder monitoring and ignition system
    • Independently controlled cylinder monitoring and ignition system
    • Pre-chamber spark plugs
  • Generator
    • grid code generator
    • Reactive droop
    • Anti-condensation space heater
    • 3-phase sensing and KVAR/PF control
    • closed-coupled generator result in no torque transmission to the base frame
    • Busbar connections
    • Reactive droop
    • Anti-condensation space heater
    • 3-phase sensing and KVAR/PF control
    • Winding temperature detectors
    • Winding temperature detectors
    • Busbar connections
  • Starting/charging
    • Battery disconnect switch
    • 24V starting motors
    • Battery disconnect switch
  • General
    • Crankshaft vibration damper and guard
    • Crankshaft vibration damper and guard

Optional Equipment

  • Air Inlet
    • Air cleaner with precleaner
    • Mounting stand
  • Cooling
    • CHP skid
    • CHP skid