Gas Generator G3512H

Maximum Electrical Efficiency
44.9%
Maximum Standby Rating
1515 eKw
Engine Model
G3512H
Maximum Continuous Rating
1515 ekW / 1505 ekW

Specs

Gas Generator Sets Specification

Maximum Electrical Efficiency
44.9%
Maximum Standby Rating
1515 eKw

Engine Specification

Engine Model
G3512H

Generator Sets Specification

Maximum Continuous Rating
1515 ekW / 1505 ekW

Generator Set Specifications

Fuel Type
Natural Gas

Generator Sets Specifications

Frequency
50 / 60 Hz
RPM
1500 rpm
Maximum Electrical Efficiency
44.90%
Maximum Standby Rating
1515 ekW / 1505 ekW

Engine Specifications

Bore
6.7in
Stroke
8.5in
Displacement
3574in³
Aspiration
TA
Engine Model
G3512H
Governor Type
ADEM A4

Generator Set Dimensions

Length
223in
Width
76in
Height
91in
Dry Weight - Genset
31085lb

Generator Set Configurations

Emissions/Fuel Strategy
U.S. EPA Stationary Emergency Certified

Features

Emissions

Meets most worldwide emissions requirements down to 0.5 g/bhp-hr Nox level without aftertreatment

Meets most worldwide emissions requirements down to 0.5 g/bhp-hr Nox level without aftertreatment

Full Range of Attachments

Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation

Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation

World Wide Product Support

Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

CAT SR5 Generator

Designed to match performance and output characteristics of Caterpillar gas engines. Industry leading mechanical and electrical design. High efficiency

Designed to match performance and output characteristics of Caterpillar gas engines. Industry leading mechanical and electrical design. High efficiency

CAT EMCP4.3 Control Panel

The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4.3 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4.3 systems can be further customized to meet your needs through programming and expansion modules.

The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4.3 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4.3 systems can be further customized to meet your needs through programming and expansion modules.

Proven System

Field proven in a wide range of apllications worldwide, fully protype tested, and certified torsional vibration analysis available

Field proven in a wide range of apllications worldwide, fully protype tested, and certified torsional vibration analysis available

CAT G3512H Gas Engine

Robust high speed block design provides prolonged life and lower owning operationg costs. Designed for maximum performance on low pressure pipeline natural gas. Simple open chamber combustion system for reliability and fuel flexibility. Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency.�One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection

Robust high speed block design provides prolonged life and lower owning operationg costs. Designed for maximum performance on low pressure pipeline natural gas. Simple open chamber combustion system for reliability and fuel flexibility. Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency.�One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection

CAT electronic control system

Simple user friendly interface and navigation. Digital monitoring, metering and protection setting. Fully-featured power metering and protective relaying. Remote control and monitor capability options

Simple user friendly interface and navigation. Digital monitoring, metering and protection setting. Fully-featured power metering and protective relaying. Remote control and monitor capability options

Standard Equipment

  • Air Inlet
    • Package Mounted Air Cleaner with service indicator
    • Single-element or two-element single-stage air cleaner with enclosure and service indicator
  • Circuit Breaker
    • 2500A 3-pole IEC rated circuit breakers, UL100% Rated
    • LSI long-time, LSI-P long-time, LSIG long-time, LSIG-P long-time options
    • Rear mounted
  • Control Panels
    • EMCP 4.3 Genset Controller
  • Cooling
    • 2nd stage CAT flange
    • ANSI class 150 JW connection
    • Engine driven water pumps for jacket water and after cooler
    • Jacket water and SCAC thermostats
  • Exhaust
    • Center section cooled turbocharger with Cat flanged outlet
    • Dry exhaust manifolds, insulated and shielded

Optional Equipment

  • Air Inlet
    • Mounting brackets and piping
    • Air cleaner with precleaner
  • Circuit Breaker Orientation
    • Frame Mounting
    • No UV trip or package CB wiring
    • 3000/3200/4000A, 3 Pole, UL100% Rated Masterpact circuit breaker (60 Hz only)
  • Control Panels
    • Language Options
    • Empty Upper Box Right/Left
    • Right/Left/Rear Extension Box
    • Cable shroud location
    • Synchronization module
    • Engine failure relay
    • Cat Connect: ethernet, satellite, cell telematics
    • Local/Remote PC Monitorring
    • Local alarm module
    • 16 point/32 light annunciator with NFPA99-110/CSA282 configuration
    • Discrete I/O module, 12 digital inputs, 8 'Form C' relay
    • Remote annunciator
  • Cooling
    • Remote radiator for JW and SCAC circuits, level switch included but not wired
    • JW heater, engine starting aid
    • inlet/outlet connections
  • Exhaust
    • 305 mm (12 in.) flange
    • Exhaust expander [250mm-329mm (10in-12in)]
    • Elbow
    • Flexible fitting [305mm x 305mm (12in. X 12in.)] w/ 12 bolt-flanges
    • Muffler options
    • 406mm (16in.) sparking-arresting muffler with companion flanges
  • Fuel System
    • Fuel filter
    • 3, 0-100 kPag, 4-20mA gas train pressure sensors
    • 1/2" NPT gas train conduit connectors
    • Gas knockdown regulators
  • General
    • US AID emblem
    • Special paint order
    • Tool set
    • Digital diagnostic tool
  • Generator
    • RTD monitoring
    • Cable access box
    • Bearing temperature detectors
    • Generator air filter
    • Medium and high voltage generators and attachment
    • Manual voltage control
  • Governing System
    • ADEM A4 4-20mA (0-5V) speed input
  • Starting/charging
    • 24V starting motors
    • Battery with cables and rack (shipped ;ppse_
    • Jacket water heater
    • 45A, 24V charging alternator (requires engine driven pumps)
    • 20A, 24VDC battery charger