Exterior View
Exterior View

C2.2 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
22.0 kVA
Minimum Rating
13.0 kVA
Emissions/Fuel Strategy
R96/EUIIIa Equivalent
Voltage
110 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime
Engine Model
Cat® C2.2, In-line 4, 4-cycle diesel
Bore
3.3in
Stroke
3.9in
Displacement
135.2in³
Compression Ratio
22.5:1
Aspiration
Naturally Aspirated
Fuel System
Indirect Injection
Governor Type
Mechanical
Length – Maximum
59.1in
Width – Maximum
24.4in
Height – Maximum
43.9in
  • Control Panel
    • GCCP 1.3
  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Cooling System
    • Radiator and cooling fan with guards
    • Caterpillar extended life coolant
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
  • Fuel System
    • Standard open set fuel tank/base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Exhaust System
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use – shipped loose
  • Generators And Generator Attachments
    • Voltage regulator (single phase sensing)
    • Segregated low voltage (AC/DC) wiring panel
    • Tower panel, IP22, bottom cable entry
    • IP23 Protection
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • 12 Leads
  • Governing System
    • Mechanical governing system
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • includes lifting provisions and termination points for coolant
  • Starting / Charging System
    • 12 Volt battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Alternator Options
    • Coastal insulation protection
  • Certificates
    • European upgrade to STD set for CE certificate
    • Global certification for CIS
  • Circuit Breakers
    • Padlockable breaker device
    • 4 Pole Circuit breaker
  • Control Panel Options
    • Emergency stop with key
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • GCCP 1.3
    • Battery charger
  • Cooling System
    • Coolant heater
  • Enclosures
    • Sound attenuated enclosure (GALV)
    • Single point lift for enclosure
  • Fuel System
    • Low fuel level alarm
  • Mounting Options
    • Industrial silencer removal
    • Silencer installation kit
    • Battery removal
  • Special Test And Inspection
    • PGS Test report @ 1.0 power factor
  • General
    • Packing case – compact set
    • Packing case – canopied set
    • Radiator stone guard