Continuous Rating
1660 ekW
Maximum Electrical Efficiency
37.70%
Maximum Standby Rating
1500
Dry Weight – Genset
31226lb
-
- Air Inlet
-
- Two-element single-stage air cleaner with enclosure and service indicator
-
- Control Panels
-
-
- Cooling
-
- Jacket water and SCAC driven pumps and bypass lines
- 2nd Stage SCAC-Cat Flange
- Engine driven water pumps for jacket water and aftercooler
- Jacket water and SCAC thermostats
- ANSI/DN customer flange connections for JW inlet and outlet
- Cat flanges on SCAC circuit
-
- Exhaust
-
- Integrated Sensing Module (ISM)
- Cat-flanged face outlet on turbocharger
- Provides exhaust port temperatures and stack temperature to customer supplied screen via CCM
- Dry exhaust manifolds, insulated and shielded
-
- Fuel System
-
- 24V ETR Gas Shutoff Valve
- Engine installed, fuel metering valve
- Throttle plate, 24V DC actuator, controlled by ECM
- Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
- Fuel Filter
-
- Ignition System
-
- Individual Cylinder Detonation Sensitive Timing (DST)
- Electronic Ignition System (controlled by ECM)
-
- Fuel System
-
- Electronic fuel metering valve
-
- Generator
-
- Anti-condensation space heater
- Busbar connections
- Class H Insulation & Class F temperature rise
- Reactive Droop
- Permanent Magnet Excitation
- 3-phase brushless, salient pole
- Caterpillar’s Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
- SR4B
- Winding temperature detectors
-
- General
-
- RH Service
- Operation and maintenance manuals
- Crankshaft Vibration Damper and Guard
- Parts Book
-
- Starting/charging
-
-
- Air Inlet
-
- Vertical, horizontal dual element air cleaner
- Enclosure mounting brackets and piping
- Air cleaner with precleaner
-
- Control Panel
-
- Local NFPA99-110 Alarm Module w/LEDs
- Synchronizing Module
- Remote 24V 8/16 Light Annunciator
- Engine Failure Relay
- PL1000E/PL1000T Communications Module
- Custom 8-Light Alarm Module
-
- Cooling
-
- Inlet/Outlet connections
- Jacket water coolant heater
- Aftercooler air lines, aftercooler core replacement
-
- Exhaust
-
- Flexible Fittings
- 14″ Flange Kit
- 406 mm Elbow Kits
- 406 mm flange kits
- Mufflers (15/18/25 dBA Attenuation) and spark-arresting muffler with ANSI companion flanges
- 16″ Spark Arresting Muffler
- 356-406mm Flange and Exhaust Expander
- 15/18/25 dBA Muffler Attenuation
-
- Fuel System
-
- 207-276kPa, 30-40 psi gas knockdown regulator
- 14-69 kPa (2-10 psi) gas pressure regulator
- 24VDC Gas Shutoff Valve, Gas Knockdown Regulator
- Fuel Filter, Gas Filter
-
- Generator
-
- Cable access box
- 8.7/15 kV Cross, Differential, Current Transformers (CCCT, DCT, CT)
- Medium and high voltage generators and attachment
- 480/4160/13200 Volt Generator Options (60 Hz)
- Generator air filter
- Bearing temperature detectors
- European Bus Bars
- 415/400/380, 3300/6600/11000 Volt Generator Options (50 Hz)
- Annunciator Modules
- Generator Removal
- Low voltage extension box
-
- Governing System
-
-
- General
-
- Special paint order
- Tool set
- US AID Emblem
- Barring group
- Digital diagnostic tool
-
- Starting/charging
-
- 60A, 24V charging alternator (requires engine driven pumps)
- Battery removal
- 20A battery charger
- Battery disconnect switch
- Battery with cables and rack (shipped loose)
Coming Soon